10 ALARMS
The appliance can provide the user with information on operational malfunctions:
Refrigerator door open too long
High temperature inside Freezer compartment
The indications and procedures for exiting refrigerator door open alarm situations are
given in the table:
The indications and procedures for exiting freezer compartment temperature alarm
situations are given in the table:
DISPLAY MODELS STANDARD MODELS
Conditions Signalling
Exiting the
alarm
condition
Signalling
Exiting the
alarm
condition
Door open > 2 minutes
Buzzer, red alarm triangle,
“door open” scrolling text
Close door,
“RESET
ALARM” key
Buzzer Close door
Door open > 4 minutes
Buzzer, red alarm triangle,
“door open” scrolling text,
REFRIGERATOR lamp flashes
Close door,
“RESET
ALARM” key
Buzzer,
Refrigerator lamp
flashes
Close door
Door open > 6 minutes
Buzzer, red alarm triangle,
“door open” scrolling text,
REFRIGERATOR lamp flashes
faster
Close door,
“RESET
ALARM” key
Buzzer,
Refrigerator lamp
flashes faster
Close door
DISPLAY MODELS STANDARD MODELS
Conditions Signalling
Exiting the
alarm
condition
Signalling
Exiting the
alarm
condition
If the temperature measured by
the FZ air sensor is HIGHER THAN
-6 °C and after 150 minutes the
temperature is above +1 °C,
alarm A1 occurs (if the
temperature is above +8° A2
occurs). If it remains between
+1 °C and -6 °C for 24 hours
A1 occurs
Buzzer, red alarm
triangle, scrolling
text on display
- Pressing the “RESET ALARM”
key once switches off the buzzer,
but does not exit the alarm
situation.
- Press the “RESET ALARM” key
twice to exit the alarm situation.
Buzzer, SUPER
FREEZE LED
(yellow) and
SUPER COOL
LED (yellow) flash
Operating the
freezer knob,
switch the
appliance off (OFF
position) and on
again
If the temperature measured by
the FZ air sensor is HIGHER THAN
-6 °C and after 150 minutes the
temperature is above +8 °C,
alarm A2 occurs . After 2 hours of
A1 without “RESET ALARM”
being pressed A2 occurs.
Buzzer, red alarm
triangle, scrolling
text on display
- Press the “RESET ALARM” key
once to switch the buzzer off, but
the alarm situation is not exited.
- Press the “RESET ALARM” key
twice to exit the alarm situation.
Buzzer, SUPER
FREEZE LED
(yellow) flashes and
SUPER COOL
LED (yellow) and
LINE LED (green)
Operate the freezer
knob to switch the
appliance off
(OFF position)
and on again