Installation Instructions
Check local codes before choosing a location. Some codes do not permit installation in a
garage, closet, mobile home or bedroom. DO NOT install the dryer in an area where
gasoline or other flammable materials are kept or stored.
When operating the dryer, there has to be adequate ventilation to avoid the back flow of
gases into the room from appliances burning other fuels, including open fires.
Minimum installation clearances:
If installed in a closet it must have the following dimensions and have two ventilation
openings each having an area 72 sq.ins (450 sq.cm) located 6" (150mm) from top and
bottom of the door. It must NEVER be installed in a closet with a solid door.
The front of the dryer has adjustable height feet, use these to level the dryer after fitting
into its final position.
The ducting system for the dryer must be as short and straight as possible and with as few
elbows as possible. Four-inch rigid metal ducting should be used. Metal flexible ducting
can be used but the maximum length of ducting if using this type will be reduced and
bends in the duct will reduce this length further. Never use plastic ducting. All elbow must
also be a minimum of 4 inch in diameter. Joints must be secured with duct tape.
Do not use screws as lint can collect on the screws.
The above assumes that an approved venting hood is used and that the flap on this hood
must not have magnetic catches.
Depending on the frequency of use it is essential that the ducting is checked periodically
and any lint or debris removed.
Where to put your dryer
Exhaust Ducting
WARNING:
The appliance MUST NOT be exhausted into a chimney, a wall, a
ceiling or a concealed space of a building.
To reduce the risk of fire, this appliance MUST BE EXHAUSTED
OUTDOORS.
Do not discharge the exhaust air into a flue which is used for
exhausting fiumes from other appliances burning gas or other fuel.
Maximum length of duct
Number of Elbows
0
1
2
3
Rigid Duct
22 ft. (6.6m)
18 ft. (5.4m)
14 ft. (4.2m)
6 ft. (1.8m)
Flexible Duct
15 ft. (4.5m)
12 ft. (3.6m)
9 ft. (2.7m)
4 ft. (1.2m)
Sides
Top
Rear
Front
Closet
4" (100mm)
15" (375mm)
3
1
/2" (90mm)
3
1
/2" (90mm)
Under Counter
0"
0"
0"
not applicable